10 • Genie HM Series Overview Genie HM Series-GigE Vision Camera
Camera Performance Specifications
Specifications for each available sensor are listed after the general Genie camera specifications.
Camera Controls
Synchronization Modes Free running
External triggered
Software trigger (through Ethernet)
Exposure Modes Programmable in increments of 1µs
minimum 10µs in Reset Mode or 56µs in Synchronous Mode
maximum is 4 seconds
Pulse controlled via Trigger pulse width.
Trigger Input Opto-isolated, 2V to 12V typical, 2mA min.
Debounce range from 1µs up to 255µs
Strobe Output
Output opto-isolated:
Aligned to the start of exposure with a programmable delay, duration and polarity
Features
LUT 8-bit (all models) / 10-bit (only HM1400 and HM1400 XDR)
Flip Real-time horizontal flip
Binning Digitally based: Horizontal (2 pixel) and Vertical (2 line)
Timestamp 1µs internal timer or external signal to timestamp images and events
Test image Internal generator with choice of static and shifting patterns
User settings Select factory default or one user camera configuration
Optical Interface
Back Focal Distance—C-Mount 17.52 mm
Back Focal Distance—CS-Mount 12.52 mm
Mechanical Interface
Camera Size 29(H) x 44(W) x 67(L) in mm, ( see Mechanical Specifications )
Mass < 125g (no lens)
Power connector 12 pin male Hirose
Ethernet connector RJ45
Electrical Interface
Input Voltage xx-GM0x-xxxxx models +11 to +25.2 Volts DC at 0.6 Amp minimum
(over voltage–reverse voltage protected)
xx-GENx-xxxxx models +11 to +15.2 Volts DC at 0.6 Amp minimum (legacy models)
Power Dissipation < 4W
Operating Temperature 0 to 45°C (at front plate)
Relative Humidity 5% to 90% non-condensing (operating)
Output Data Configuration Gigabit Ethernet (IEEE 802.3)
Data and Control GigE Vision compliant at 1000 or 100 Mbps