Spyder3 Camera User’s Manual SG-11-01k80-00-R SG-11-02k80-00-R SG-11-04k80-00-R SG-11-01k40-00-R SG-11-02k40-00-R GigE Vision Dual Line Sc
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 10 Tap1CCDReadoutShiftReg isterCCDReadout ShiftRegisterNPixels(14μmx14μm)NPixe
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 11 CCDReadoutShiftRegisterCCDReadoutShiftRegisterSensor2(14μmx14μmOR10μmx
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 12 1.4 Responsivity Figure 6: Spyder3 GigE Vision 1k and 2k Responsivity Spectral Responsi
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 13 1.5 Supported Industry Standards Spyder GEV cameras are 100% compliant with the G
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 14
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 15 2 Mechanicals and Optics 2.1 Mechanical Interface Figure 8: Spyder3 1k and 2k GigE
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 16 Figure 9: Spyder3 4k GigE Vision Camera Mechanical Dimensions ø62.0 - 4.5 DEEPM3X0.5 T
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 17 2.2 Mounting DALSA recommends that you allow the heat generated by the camera to mov
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 18 • LED light sources are relatively inexpensive, provide a uniform field, and longer li
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 19 3 Setting Up the Camera 3.1 Installation Overview 1. Install Ethernet card Following
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 2 © 2010 DALSA. All information provided in this manual is believed to be accurate and rel
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 20 4. Connect GPIO cable If using an external sync, external direction control, or any oth
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 21 3.2 Equipment Recommendations PC Requirements To achieve best performance, the follo
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 22 eBus Optimal Driver The eBus Optimal Driver is our recommended driver for applications
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 23 Standard Driver Mode In standard mode, the Spyder3 GEV operates with any vendor’s Et
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 24 !3.4 Camera Connectors This camera uses the following connectors: • An RJ-45 connect
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 25 !Steady yellow indicates that the camera is ready for data transmission. Flashing ye
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 26 GPIO Connector The GPIO connector is used to receive or control external signals. For e
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 27 TTL Inputs and Outputs Figure 13: TTL Input Schematic 1000Ω3.3V3.3VTTL • Terminati
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 28 GPIO Isolation All of the GPIOs are isolated from the rest of the camera and the camera
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 29 4 EMC Declaration Dalsa's SG-11 cameras meet the requirements outlined below wh
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 3 Contents Spyder3 GigE Vision Camera _______________________________________________ 5
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 30
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 31 5 Controlling the Camera To control the camera, you have a choice of using the follo
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 32 Min 300 Hz, Max 18500 Hz BinningHorizontal sbh set binning horizontal Min 1, Max 2 Bl
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 33 [GPIOSelector] GPIOSelector GPIO selector for sgi and sgo. Height This feature
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 34 5.3 First Power Up Camera Settings When the camera is powered up for the first time, it
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 35 Sensor Shift Direction When in high sensitivity mode, you can select either forward
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 36 5.5 Timing: Exposure and Synchronization Image exposures are initiated by an event. The
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 37 27.78 1000 2K 2 Tap 54.1 1000 4k 2 Tap twSync ns 100 twSYNC_INT
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 38 Exposure Mode, Readout Mode, Line Rate and Exposure Time Overview You have a choice of
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 39 Exposure Modes in Detail Mode 2: Internally Programmable Line Rate and Exposure Time
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 4 5.7 Data Processing...
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 40 Mode 4: Smart EXSYNC, External Line Rate and Exposure Time In this mode, EXSYNC sets b
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 41 Mode 7: Internally Programmable Line Rate, Maximum Exposure Time In this mode, the l
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 42 Setting the Readout Mode Refer to the Clearing Dark Current section, page 62, for more
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 43 5.6 Configuring the GPIO Connector The following commands provide a connection betwe
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 44 5.7 Data Processing Processing Chain Overview and Description The following diagram sho
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 45 at only 50% of the DN. An analog gain of 6 dB (2x) will ensure full use of the dynam
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 46 Sets the camera’s analog gain value. Analog gain is multiplied by the analog signal to
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 47 Setting Analog Offset Sets the analog offset. The analog offset should be set so tha
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 48 The white light calibration is performed next to determine the multiplication factors r
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 49 Set up the camera operating environment(i.e. line rate, exposure, offset, gain, etc.
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 5 1 Spyder3 GigE Vision Camera 1.1 Camera Highlights Features and Programmability • Br
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 50 Digital Signal Processing To optimize camera performance, digital signal processing sho
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 51 Performing PRNU to a user entered value Performs PRNU calibration to user entered va
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 52 incorrect PRNU coefficients. This algorithm is more robust and repeatable than algorith
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 53 correction wizard. For easy flat field correction, use the wizard located on the Cal
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 54 Setting Digital System Gain Improves signal output swing after a background subtract. W
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 55 Location Value Description 3 A’s 4 4 bit counter LSB justified Counter incremen
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 56 Look-Up Tables Note: This information only applies to the 4k model camera. The flat fie
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 57 • To restore the last saved pixel coefficients, use the command LoadPixelCoefficien
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 58 DeviceReset 5.9 Diagnostics Generating a Test Pattern Generates a test pattern to aid i
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 59 Ethernet Test Pattern A third test pattern—Ethernet—is accessible using the QuickCam
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 6 Description and Applications The Spyder3 GEV is also DALSA’s first dual line scan camera
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 60 Returning the LED Status Returns the status of the camera’s LED. LEDStatus The camera r
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 61 Message Description Message Description Error 02: Unrecognized command> Command
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 62 5.11 Clearing Dark Current Gate Dark Current Clear Image sensors accumulate dark curren
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 63 SG-11-02K80 13.6KHz 16.4KHz Immediate read out mode (default, ReadoutMode 2) In th
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 64 Auto Mode (Auto) In this mode the line rate from the camera will automatically cause
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 65 0HzWatchdogFrequencyMax. Line Rate inImmediateReadout ModeIncreasing Line RateFrequ
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 66 ReadoutMode 2, Immediate Readout Mode. Time Period Operating Region Refer to Figure 23.
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 67 Dark Current Dump to Immediate Readout (TINT > #) TVERT_TRANSFDUMP LVA L FIMMEDI
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 68 Dark Current Dump to Immediate Readout (TINT < #) TVERT_TRANSLVA LEXSYNCTDUMPTINTFDU
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 69 Immediate Readout to Dark Current Dump: Hysteresis Artifacts ReadoutMode 0, Auto Mod
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 7 1.2 Camera Performance Specifications Table 2: Spyder3 GigE Vision Camera Performance
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 70 Setting the Readout Mode Use this command to clear out dark current charge in the ver
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 71 Appendix B ASCII Commands All the functionality available through the QuickCam GUI
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 72 Figure 24: Command Tab after Sending the sem (Set Exposure Mode) Command Configuration
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 73 Virtual Serial Port Method 1. Open QuickCam. 2. Select Configure → Serial Port Lin
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 74 gcp <CR> Camera ASCII Command Help For quick help, the camera can return
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 75 Mnemonic Syntax Parameters Description calculate camera gain ccg i t i Calculates
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 76 Mnemonic Syntax Parameters Description calculate PRNU algorithm cpa i i Performs PRN
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 77 Mnemonic Syntax Parameters Description enable input LUT eil i Enable input LUT, w
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 78 Mnemonic Syntax Parameters Description get signal frequency gsf i Reads the requeste
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 79 Mnemonic Syntax Parameters Description set analog offset sao t i Sets the analog
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 8 Feature / Specification 1k 2k 4k Data Rate 40 or 80 MHz, model dependent 40 or 80 MH
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 80 Mnemonic Syntax Parameters Description set exposure time set f Sets the exposure tim
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 81 Mnemonic Syntax Parameters Description set sync frequency ssf i Set the frame rat
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 82
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 83 Appendix D Troubleshooting The information in this chapter can help you solve proble
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 84 If you change to an exposure mode that requires an external sync, then ensure that you
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 85 4. Click Save. To view the error report: 1. Select View → Error Report. In the Ope
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 86 end. The goal is to prevent solvent from evaporating from the window surface, as this w
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 87 Product Support If there is a problem with your camera, collect the following data a
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 88
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 89 Appendix E Revision History Revision Number Change Description 00 Preliminary relea
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 9 Dual line 4.6 4.5 4.6 Single line 9.2 9.3 9.2 4k Du
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 90
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 91 Index A analog gain, 45, 46, 47 processing, 44 ASCII commands, 71 complete list, 7
Spyder3 GigE Vision User Manual 03-032-20027-02 DALSA 92 commands, 31 description of, 13 interface, 31 website, 13 GigE Vision description of, 1
Spyder3 GigE Vision User’s Manual DALSA 03-032-20027-02 93 sensor, 9 serial interface defaults, 73 settings factory, 34 restoring, 56 saving, 5