52 Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual
03-032-20123-01 Teledyne DALSA
GigE Vision Input Controls
Advanced Processing
Parameter
Description
FFC Coefficient Set No.
Selects the pixel set to load, or save. There are 4 user sets available.
Load FFC Coefficient
Loads the Flat Field Correction Coefficients (specified by the Pixel Set
Selector) from the cameras non-volatile memory.
Reset FFC Coefficients
Restores the cameras pixel coefficients to 0 for FPN and a PRNU factor of 1.
This command does not reset saved coefficients.
Save PRNU
Write all current PRNU coefficients to non-volatile memory when Pixel Set
Selector is not Default
Save FPN
Write all current FPN coefficients to non-volatile memory when Pixel Set
Selector is not Default
FPN Calibrate
Perform a Fixed Pattern Noise calibration. Please block all light from entering
the camera(i.e. cover the lens). *** WARNING: This command can take up to
3 seconds. Please adjust the GUI's timeout values
Target to Calibrate PRNU
The target value for the PRNU calibration algorithm
PRNU Calibrate
Calibrate PRNU coefficients. Ideally FPN calibration should be done before
the PRNU calibration. To calibration PRNU, the direction must not be
External. Always set proper target before click this button. *** WARNING:
This command can take up to 15 seconds.
FPN Enable
Enables and disables the fixed pattern noise correction
PRNU Enable
Enables and disables the photo response non-uniformity correction
Calibration Result
Displays the result from the flat field calibration.
Read FFC Calibration
Result
Read FFC Calibrate Result
Region of Interest X
The horizontal start of the region of interest. The region of interest is used
specify which part of the sensor to calibrate.
Region of Interest Width
The width of the region of interest. The region of interest is used specify
which part of the sensor to calibrate