Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual 77
Teledyne DALSA 03-032-20123-01
Triggered on rising edge: Indicates if a triggered pulse generator is triggered on the rising edge of an
input
Triggered on high level: Indicates is a triggered pulse generator is triggered on the high level of an
input
Triggered on falling edge: Indicates if a triggered pulse generator is triggered on the falling edge of
an input
Triggered on rising AND falling edges: Indicates if a triggered pulse generator is triggered on the
rising edge of an input and on the falling edge of an input
Triggered on low level: Indicates if a triggered pulse generator is triggered on the low level of an
input
Pulse Period (ns)
Displays the value of the parameter, in nanoseconds, of a complete delay-width cycle of the pulse
generator. This value is computed every time the delay, width or granularity is modified and is available
regardless of the periodic mode.
Pulse Frequency (Hz)
Displays the frequency of the pulse generator. This value is computed every time the delay, width or
granularity is modified and is available regardless of the periodic mode.
Pulse Generator Timing
Positive Pulse Generated from a Rising Edge Trigger
Trigger
Pulse_Out
pulse_delay pulse_width
Negative Pulse Generated from a Level High Trigger
Trigger
Pulse_Out
pulse_delay pulse_width
The
software can generate two internal signals using the internal pulse generators. The behavior of each of
these two pulse generators is defined by a delay and a width . As shown in the accompanying diagrams,
the delay is the time between the trigger and the pulse transitions. The width is the time the pulse stays at
the active level before transitioning. The periodic mode, the delay determines the low time of the pulse.
Each pulse generator generates a signal that can be used as an input to the GPIO Control Block. A
triggered pulse generator needs an input signal that comes from an output of the GPIO Control Block.
Note: There is one clock cycle between the output signal of a pulse generator and the outputs of the GPIO
Control Block.
The labels for the inputs from the pulse generators in the GPIO Control Block programming languages
are:
I7, for pulse generator 0
Vista de pagina 76