64 Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual
03-032-20123-01 Teledyne DALSA
In the Sensor Control Group > set the desired exposure mode, exposure time and line rate.
Figure 38: Exposure Mode, Time, and Line Rate Settings
Internal Line Trigger, External Direction Control, Internal frame
trigger
Set the Frame Start Trigger and Frame Active Trigger values to off, as described above. Set the Line
Trigger Mode value to Off and the Exposure Mode, Exposure Time and Line Rate as above.
In the Direction Control Group > set the Sensor Scan Direction to External.
Set the Input Direction Signal to Line 2 (as described at the start to this section).
Figure 39: Scan Direction