Dalsa Spyder3 Manual de usuario Pagina 57

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 104
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 56
Spyder3 GigE Vision SG-14 Monochrome Cameras User’s Manual 57
Teledyne DALSA 03-032-20123-01
SG-14-02K40-00-R
53.1µs
SG-14-02K80-00-R
27.5 µs
SG-14-04K80-00-R
53.1µs
Setting the Readout Mode
Use this command to control dark current in the vertical transfer gates.
Camera Link Command
Parameter
Description
Notes
srm
0: Auto. Clears dark current below ~
30-45% of the maximum line rate
1: Dark current clear. Always clears
dark. Reduces the maximum line rate.
2: Immediate readout. Does not
clear dark current. (Default mode)
The vertical transfer gates collect dark current
during the line period. This collected current is
added to the pixel charge.
If the user is in sem 2 or 7 and srm 2, with
ssf at 45% of the maximum (~ 30% in HS
mode), and then srm 1 is selected, the following
warning will be displayed, but the ssf value will
not be changed: Warning 09: Internal line rate
inconsistent with readout time> The effect in
both internal and external line rate modes is that
an EXSYNC is skipped and, therefore, the
output will be at least twice as bright.
This value is saved with the camera settings.
This value may be viewed using either the gcp
command or the get srm command.
Example
srm 0